HP to LP Storage Regulator 6000 psi > 400 psi CGA 347 | PB415-347-LP

$439.00

Designed for regulating high-pressure (HP) storage pressure to low-pressure (LP) regulated supply. High quality, piston type, hand load reducing regulator. Inlet pressure: 6000 psi. Outlet pressure: 0–400 psi. Comes with CGA347 nut nipple and two (2) stainless steel, liquid-filled pressure gauges with 2.5 in dials; one reads storage pressure and one reads regulated pressure.

SKU
PB415-347-LP

The model 415 reducing regulator is a piston type, hand load regulator that uses an unbalanced poppet design for ruggedness and simplicity. There is a small variation of control pressure with changing inlet pressure as noted in the specifications. A 30 micron filter in the poppet cartridge helps prevent damage by contaminants.

Regulator Specifications

Type Reducing Regulator
PSI Out 0 to 400 psi
Hand Loaded/Operated or Dome/Air Operated Hand/Spring Loaded
Maximum Rated Pressure 6000 psi
Outlet Pressure Range 50-400 psi
Outlet Pressure Rating 6000 psi
Inlet Port Size 2 ea 1/4 in FNPT (One Gauge, One Inlet)
Outlet Port Size 2 ea 1/4 in FNPT (One Gauge, One Outlet)
Flow Coefficient (Cv) 0.06 (equals 0.07 in orifice)
Outlet Pressure Variations with Inlet Pressure Variations 6 psi rise/1000 psi inlet drop
Leakage Bubble tight
Weight 25 oz (710 g)
Overall Length 5.5 in (13.97 cm)
Round Diameter 2.25 in (5.715 cm)
Minimum Temperature -15ºF (-26°C)
Body Materials Anodized aluminum
Internal Materials Anodized aluminum, Brass, Stainless
Seal Materials Kel-F, Viton
Special Note Not oxygen cleaned
Loading...