Repackable Filter Catridges & Elements

Nuvair stocks a variety of repackable (refillable) compressor filter cartridges.
SKU

Product Descriptions

SKU Description
SC000440 Refillable compressor cartridge filter filled with molecular sieve and activated carbon. Removes moisture, hydrocarbons, oil, taste/odor and particles. For use in MCH8-MCH23 compressors.
SC000440-CNG Refillable CNG compressor cartridge filter filled with molecular sieve removes moisture, hydrocarbons, carbon dioxide, and organics. Customers can return the cartridge for repacking or Nuvair can ship molecular sieve refilling onsite. For CNG compressor use only. Designed for Coltri MCH5 CNG, MCH10 CNG, and MCH14 CNG compressors.
SC000440-MC Repackable high-pressure filter cartridge containing molecular sieve and activated carbon. Made of polypropylene. For use in Nuvair 7-9; Coltri MCH8-MCH16, MCH26 and MCH32; Max Air 90, and Poseidon compressors. Suggested for paintball and industrial use. Not for breathing air applications. Dimensions: 1.75" OD x 14.125" L.
SC000543-CNG Refillable CNG compressor cartridge filter filled with molecular sieve removes moisture, hydrocarbons, carbon dioxide, and organics. Customers can return the cartridge for repacking or Nuvair can ship molecular sieve refilling onsite. For CNG compressor use only. Designed for Coltri MCH24 CNG compressor.
GO36 Anodized aluminum top. 304 stainless steel tube. Uses 2.5 in pads.
4341-01-REPACK Repacakable filter cartridge for the Norgren Excelon F74V vapor removal filter. Stainless steel.

Filter Cartridge Warnings

DO NOT drop filter into housing.
REPLACE FILTERS AS A SET.
DO NOT use where operating temperature could exceed 120°F (49ºC). Use of a temperature alarm is recommended.
HEAT & HUMIDITY shorten filter life.
DO NOT introduce large slugs of water into filter.
BLOW all lines and parts clear prior to installation.
DO NOT use where pressure surges are likely.
DO NOT use in system without earth ground.
REMOVE all protective seals and closures.
NOT FOR use in aircraft.
ALWAYS follow standard operating procedures (SOP) for producing breathing gases.
MAXIMUM USEFUL LIFESPAN is six months. Shelf life is two years.